Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 10.765
Filtrar
2.
Sci Rep ; 14(1): 8953, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637547

RESUMO

Although oxytocin (OT) plays a role in bonding between heterospecifics and conspecifics, the effects of OT on the formation of such interspecific social behavior have only been investigated between humans and dogs (Canis familiaris). In this study, for comparative evaluation of the effects of OT between dog-human and cat-human social interaction, we investigated the effects of exogenous OT on the behavior of domestic cats (Felis silvestris catus) toward humans. We intranasally administered OT or saline to 30 cats using a nebulizer and recorded their behavior (gaze, touch, vocalization, and proximity). The results showed an interaction between the administration condition and sex for gaze duration. Post hoc analyses revealed a significant increase in gaze in the OT condition in male cats but not in females. There were no significant differences in gaze toward owners and strangers in any condition or sex. The male-specific OT-mediated increase in gaze toward humans observed in this study differs from previous research on dogs wherein such effects were observed only in females. These findings suggest an overall effect of exogenous OT on cats' social relationship with humans as well as the possibility of different mechanisms between cat-human and dog-human relationships.


Assuntos
Ocitocina , Comportamento Social , Feminino , Humanos , Gatos , Animais , Masculino , Cães , Ocitocina/farmacologia , Relações Interpessoais , Interação Social , Nebulizadores e Vaporizadores
3.
BMC Pulm Med ; 24(1): 189, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38641584

RESUMO

BACKGROUND: Nonadherence to therapies and psychological disorders are associated with poor asthma control. This study aims to assess the prevalence of anxiety and depressive symptoms, asthma control, and adherence to inhalers and to investigate whether there is an association of anxiety and depressive symptoms with adherence to inhalers and asthma control. METHODS: We measured anxiety and depressive symptoms using the Hospital Anxiety and Depression Scale in patients with asthma. Asthma Control Test and the 10-Item Test of Adherence to Inhalers Scale were used to assess levels of asthma control adherence to inhalers, respectively. Univariate and multivariate regression models assessed the associations of anxiety and depressive symptoms with adherence to inhalers and asthma control. RESULTS: A total of 287 patients completed the study, of whom 72% were female. The mean ± SD age and body mass index of our study population were 44 ± 13 years and 29 ± 7.2 kg/m2, respectively. Poor adherence to inhaler use was highly prevalent (49.8%; 95% CI: 43.8 to 55.7). The prevalence of anxiety, depression and poor asthma control was 27.2% (95% CI: 22.1 to 32.7), 20.9% (95% CI: 16.3 to 26.1), and 22.7% (95% CI: 17.9 to 27.9), respectively. We found a negative relationship between asthma control and anxiety, and depressive symptoms (adjusted ß: -0.25; 95% CI: -0.36 to -0.14; p < 0.001 and adjusted ß: -0.29; 95% CI: -0.40 to -0.18; p < 0.001, respectively). A negative relationship was also observed between adherence to inhalers and anxiety and depressive symptoms (adjusted ß: -0.34; 95% CI: -0.46 to -0.22; p < 0.001 and adjusted ß: -0.36; 95% CI: - 0.48 to - 0.24; p < 0.001, respectively). CONCLUSIONS: The high prevalence of uncontrolled asthma symptoms and poor adherence to inhalers and their impact on anxiety and depression levels among patients with asthma point to the need for early screening for psychological symptoms and recognition of nonadherence as part of asthma assessment and management plan in primary care in Saudi Arabia to avoid further worsening of asthma symptoms. Further studies are needed to explore the effectiveness of specific psychoeducational interventions and investigate the long-term impact of early psychological symptom detection on asthma outcomes.


Assuntos
Antiasmáticos , Asma , Humanos , Feminino , Masculino , Estudos Transversais , Antiasmáticos/uso terapêutico , Asma/tratamento farmacológico , Asma/epidemiologia , Asma/psicologia , Adesão à Medicação , Nebulizadores e Vaporizadores
4.
Lancet Planet Health ; 8 Suppl 1: S5, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38632920

RESUMO

BACKGROUND: The carbon footprint of Canada's health sector is among the worst in the world, responsible for 4·6% of Canada's total greenhouse gas emissions. A quarter of emissions from Canada's health sector are linked to pharmaceuticals, including metered dose inhalers (MDIs). MDIs use propellants, such as hydrofluorocarbons, which act as greenhouse gas emissions and contribute to the health-care sector's overall carbon footprint. The objective of this study was to describe MDI prescribing, dispensing, usage, and waste patterns at The Ottawa Hospital (Ottawa, ON, Canada). Secondary objectives included estimating the monetary and carbon cost of current practice and the potential benefits and costs of switching to the more environmentally friendly dry powder inhalers. METHODS: In this retrospective point-prevalence cohort study, we identified 100 consecutive patients from medical and surgical services at both campuses of The Ottawa Hospital from health records discharged from medical and surgical services and who were prescribed at least one MDI during their admission. Medical records were reviewed and data related to demographics, MDI prescribing, dispensing, usage, and wastage were collected using a pre-piloted electronic case report form. Financial cost was calculated using local costing estimates and carbon cost was calculated using published estimates. FINDINGS: Between Jan 1, 2023, and June 1, 2023, we collected data for 100 eligible patients, of whom 60 (60%) were female and 90 (90%) were admitted to hospital medicine wards (10% from surgical wards). The median length of stay was 7 (range 1-47) days. The most common inpatient diagnoses were respiratory tract infections in 43 (43%) of 100 patients and chronic obstructive pulmonary disease exacerbations in 28 (28%) of 100 patients. The median number of MDIs prescribed during a patients stay was two (range one to 15) and the median number dispensed was one (range one to seven). For formulary options of MDIs, of the 200 (range 30-1400) actuations dispensed per patient, 8% were used, representing 92% wastage. During the audit, 315 MDIs were dispensed in total, of which 97 were not used at all. INTERPRETATION: MDIs are significant contributors to the carbon footprint attributed to pharmaceutical use in hospitals. This study suggests that 90% of MDI doses are wasted, showing that there is substantial room for improvement. FUNDING: None.


Assuntos
Gases de Efeito Estufa , Humanos , Feminino , Masculino , Estudos de Coortes , Estudos Retrospectivos , Nebulizadores e Vaporizadores , Inaladores Dosimetrados , Hospitais , Carbono
5.
BMJ Open Respir Res ; 11(1)2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38626929

RESUMO

BACKGROUND: Errors using inhaled delivery systems for COPD are common and it is assumed that these lead to worse clinical outcomes. Previous systematic reviews have included patients with both asthma and COPD and much of the evidence related to asthma. More studies in COPD have now been published. Through systematic review, the relationship between errors using inhalers and clinical outcomes in COPD, including the importance of specific errors, was assessed.MethodsElectronic databases were searched on 27 October 2023 to identify cohort, case-control or randomised controlled studies, which included patients with COPD, an objective assessment of inhaler errors and data on at least one outcome of interest (forced expiratory volume in 1 s, (FEV1), dyspnoea, health status and exacerbations). Study quality was assessed using the Newcastle and Ottawa scales. A narrative synthesis of the results was performed as there was insufficient detail in the publications to allow quantitative synthesis. There was no funding for the review. RESULTS: 19 publications were included (7 cohort and 12 case-control) reporting outcomes on 6487 patients. 15 were considered low quality, and most were confounded by the absence of adherence data. There was weak evidence that lower error rates are associated with better FEV1, symptoms and health status and fewer exacerbations. Only one considered the effects of individual errors and found that only some were related to worse outcomes. CONCLUSION: Evidence about the importance of specific errors using inhalers and outcomes would optimise the education and training of patients with COPD. Prospective studies, including objective monitoring of inhalation technique and adherence, are needed. PROSPERO REGISTRATION NUMBER: CRD42023393120.


Assuntos
Asma , Doença Pulmonar Obstrutiva Crônica , Humanos , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Estudos Prospectivos , Nebulizadores e Vaporizadores , Dispneia
6.
Artigo em Inglês | MEDLINE | ID: mdl-38562440

RESUMO

Objective: To comparison of the application of Vibrating Mesh Nebulizer and Jet Nebulizer in chronic obstructive pulmonary disease (COPD). Research Methods: This systematic review and meta-analysis was conducted following the Preferred Reporting Items for Systematic Review and Meta-analyses (PRISMA) statements. The primary outcome measures analyzed included: The amount of inhaler in the urine sample at 30 minutes after inhalation therapy (USAL0.5), The total amount of inhaler in urine sample within 24 hours (USAL24), Aerosol emitted, Forced expiratory volume in 1 second (FEV1), Forced vital capacity (FVC). Results: Ten studies were included with a total of 314 study participants, including 157 subjects in the VMN group and 157 subjects in the JN group. The data analysis results of USAL0.5, MD (1.88 [95% CI, 0.95 to 2.81], P = 0.000), showed a statistically significant difference. USAL24, MD (1.61 [95% CI, 1.14 to 2.09], P = 0.000), showed a statistically significant difference. The results of aerosol emitted showed a statistically significant difference in MD (3.44 [95% CI, 2.84 to 4.04], P = 0.000). The results of FEV1 showed MD (0.05 [95% CI, -0.24 to 0.35], P=0.716), the results were not statistically significant. The results of FVC showed MD (0.11 [95% CI, -0.18 to 0.41], P=0.459), the results were not statistically significant. It suggests that VMN is better than JN and provides higher aerosols, but there is no difference in improving lung function between them. Conclusion: VMN is significantly better than JN in terms of drug delivery and utilization in the treatment of patients with COPD. However, in the future use of nebulizers, it is important to select a matching nebulizer based on a combination of factors such as mechanism of action of the nebulizer, disease type and comorbidities, ventilation strategies and modes, drug formulations, as well as cost-effectiveness, in order to achieve the ideal treatment of COPD.


Assuntos
Broncodilatadores , Doença Pulmonar Obstrutiva Crônica , Humanos , Administração por Inalação , Albuterol , Broncodilatadores/efeitos adversos , Sistemas de Liberação de Medicamentos , Desenho de Equipamento , Nebulizadores e Vaporizadores , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Aerossóis e Gotículas Respiratórios
7.
Swiss Med Wkly ; 154: 3394, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38579300

RESUMO

AIMS OF THE STUDY: Misuse of inhalers during chronic obstructive pulmonary disease (COPD) treatment is common and may result from errors in inhalation technique or insufficient peak inspiratory flow (PIF). We aimed to evaluate the impact of an in-hospital intervention to reduce inhaler misuse at hospital discharge among patients with COPD. METHODS: We conducted a monocentric, non-randomised intervention study to compare the proportion of misused inhalers at hospital discharge by patients with COPD between a group with standard care and a group receiving an in-hospital intervention. The control group successively included all patients hospitalised between March and June 2022, and the intervention group included patients hospitalised between August and December 2022. The intervention consisted of (a) an evaluation of inhalation technique and PIF at admission, (b) the provision of a written guide to assist in the selection of an inhaler, and (c) therapeutic education. The primary outcome was the proportion of misused inhalers, defined as an inhaler used with a critical error and/or insufficient PIF, at hospital discharge. The primary outcome was assessed by observing inhalation technique and measuring PIF using the In-Check DIAL G16® . RESULTS: The study included 93 patients: 46 in the control group and 47 in the intervention group. Mean age was 70.5 years (SD 10.9 years), 56 patients (60.2%) were men, and 57 patients (62%) were hospitalised for a COPD exacerbation. Patients used an average of 1.9 inhalers at hospital discharge; 98 inhalers were assessed in the control group and 81 in the intervention group. The proportion of misused inhalers at discharge was 61.2% in the control group and 21.0% in the intervention group (absolute risk reduction 40.2% [95% CI 25.5-55.0]; p <0.01). In the intervention group, the proportion of inhalers used with at least one critical error was reduced by 38.6% (95% CI 24.3-52.3%) and that of inhalers used with insufficient PIF by 13.9% (95% CI 4.2-23.6%). CONCLUSIONS: An in-hospital intervention was associated with a reduction in the proportion of misused inhalers at hospital discharge. This intervention should be considered for hospitalised patients with COPD. The trial was registered with ClinicalTrials.gov (NCT05207631).


Assuntos
Alta do Paciente , Doença Pulmonar Obstrutiva Crônica , Masculino , Humanos , Idoso , Feminino , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Nebulizadores e Vaporizadores , Hospitalização , Hospitais , Administração por Inalação
8.
BMJ Paediatr Open ; 8(1)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38555100

RESUMO

BACKGROUND: Pyrethroid-based mosquito repellents are widely used to control mosquito-borne diseases. Liquid mosquito-repellent vaporisers are effective modes of pyrethroid delivery but can also pose significant health risks if ingested or used improperly. OBJECTIVE: This systematic review was performed to assess the demographic distribution, clinical presentation, management strategies and outcomes in children resulting from accidental ingestion of liquid mosquito repellent vaporiser. METHODS: The study adheres to the reporting standards outlined in the PRISMA Statement for Systematic Reviews and was prospectively registered with PROSPERO (record # CRD42023413937) to enhance transparency and minimise reporting bias. A comprehensive search was conducted on PubMed, Scopus and Google Scholar using specific MeSH terms related to insecticides, mosquito repellents, pyrethroids, ingestion, poisoning, toxicity and prevention. The reference lists of the included studies were also reviewed for additional relevant articles. The inclusion criteria involved studies published in peer-reviewed journals between 2000 and 2023 that focused on children under 18 years old with a history of mosquito-repellent ingestion based on primary data. RESULTS: Twelve studies met the inclusion criteria; these were primarily case reports from India, China and the UAE. Male children were predominantly affected, and symptoms included vomiting, convulsions, cough and respiratory distress. Management primarily involved supportive and symptomatic measures, including atropine for salivation and antiepileptic drugs for seizures. Respiratory support was provided for respiratory complications. CONCLUSION: Despite the known risks and diverse presentations of pyrethroid poisoning caused by liquid mosquito repellent vaporiser in children, the limited substantial evidence in the literature underscores the urgent need for comprehensive research to refine management approaches and enhance preventive measures.


Assuntos
Repelentes de Insetos , Inseticidas , Piretrinas , Criança , Animais , Humanos , Masculino , Adolescente , Nebulizadores e Vaporizadores , Ingestão de Alimentos
9.
COPD ; 21(1): 2327345, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38509685

RESUMO

Type 2 diabetes is a frequent comorbidity in chronic obstructive pulmonary disease (COPD) patients, with the GOLD treatment recommendations asserting that the presence of diabetes be disregarded in the choice of treatment.In a cohort of COPD patients with frequent exacerbations, initiators of single-inhaler triple therapy or dual bronchodilators were compared on the incidence of COPD exacerbation and pneumonia over one year, adjusted by propensity score weighting and stratified by type 2 diabetes.The COPD cohort included 1,114 initiators of triple inhalers and 4,233 of dual bronchodilators (28% with type 2 diabetes). The adjusted hazard ratio (HR) of exacerbation with triple therapy was 1.04 (95% CI: 0.86-1.25) among COPD patients with type 2 diabetes and 0.74 (0.65-0.85) in those without. The incidence of severe pneumonia was elevated with triple therapy among patients with type 2 diabetes (HR 1.77; 1.14-2.75).Triple therapy in COPD is effective among those without, but not those with, type 2 diabetes. Future therapeutic trials in COPD should consider diabetes comorbidity.


Triple therapy for frequent COPD exacerbators is effective in patients without type 2 diabetes but not in those with type 2 diabetes. The impact of comorbidities should be considered in future COPD therapeutic trials.


Assuntos
Diabetes Mellitus Tipo 2 , Pneumonia , Doença Pulmonar Obstrutiva Crônica , Humanos , Doença Pulmonar Obstrutiva Crônica/complicações , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Broncodilatadores , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/tratamento farmacológico , Agonistas de Receptores Adrenérgicos beta 2/uso terapêutico , Administração por Inalação , Quimioterapia Combinada , Antagonistas Muscarínicos/uso terapêutico , Nebulizadores e Vaporizadores , Comorbidade
10.
Pharm. pract. (Granada, Internet) ; 22(1): 1-12, Ene-Mar, 2024. tab
Artigo em Inglês | IBECS | ID: ibc-231377

RESUMO

Purpose: Asthma is a chronic condition affecting millions of people all around the world. Asthma has no cure, but disease control is essential and highly recommended. However, the available tools for asthma control assessment don’t include factors such as inhaler technique and adherence. This study aimed to assess the correlation between inhaler techniques, adherence, and level of asthma control in two different healthcare settings; Jordan and Iraq. Patients and methods: A cross-sectional observational study was con-ducted over six months, from January to August 2018, in two public hospitals in Amman (Jordan) and Baghdad (Iraq). Asthmatic patients were interviewed to assess their inhaler technique, adherence, and asthma control. The researcher personally visited both public hospitals, conducting face-to-face interviews with patients at the hospital outpatient clinics. Validated questionnaires were used for patient assessment, including demographics, asthma history and medication use, the patient’s inhaler technique, adherence, and asthma control. Results: A total of 300 patients entered the study, with a mean age of 45.54 ± 13.71. The asthma control test showed very poor asthma control for patients living in both countries (Amman n=78 (52.0%) vs. Baghdad n=106 (70.0%)). An asthma knowledge assessment showed that most asthmatic patients in both countries didn’t follow their asthma medication plan (Amman n=78 (52.0%) vs. Baghdad n=93 (62.0%). Conclusion: In both Jordan and Iraq, asthma patients were found to be poorly controlled. Knowledge of patients was inadequate, probably leading to the poorly managed chronic disease. The results of this study highlight the significance of the pharmacist’s role in recognizing asthmatic patients requiring assistance. Furthermore, they underscore the pharmacist’s pivotal contribution to delivering patient education and counseling, ultimately resulting in enhanced asthma control. (AU)


Assuntos
Humanos , Asma , Doença Crônica , Nebulizadores e Vaporizadores , Israel , Hospitais Públicos , Cooperação do Paciente , Jordânia , Estudos Observacionais como Assunto , Estudos Transversais
11.
Respir Care ; 69(4): 395-406, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38538026

RESUMO

BACKGROUND: Aerosol barrier enclosure systems have been designed to prevent airborne contamination, but their safety has been questioned. A vacuum tent was designed with active continuous suctioning to minimize risks of aerosol dispersion. We tested its efficacy, risk of rebreathing, and usability on a bench, in healthy volunteers, and in an ergonomic clinical assessment study. METHODS: First, a manikin with airway connected to a breathing simulator was placed inside the vacuum tent to generate active breathing, cough, and CO2 production; high-flow nasal cannula (HFNC) was applied in the manikin's nares. Negative pressure was applied in the vacuum tent's apex port using wall suction. Fluorescent microparticles were aerosolized in the vacuum tent for qualitative assessment. To quantify particles inside and around vacuum tent (aerosol retention), an airtight aerosol chamber with aerosolized latex microparticles was used. The vacuum tent was tested on healthy volunteers breathing with and without HFNC. Last, its usability was assessed in 5 subjects by 5 different anesthesiologists for delivery of full anesthesia, including intubation and extubation. RESULTS: The vacuum tent was adjusted until no leak was visualized using fluorescent particles. The efficacy in retaining microparticles was confirmed quantitatively. CO2 accumulation inside the vacuum tent showed an inverse correlation with the suction flow in all conditions (normal breathing and HFNC 30 or 60 L/min) in bench and healthy volunteers. Particle removal efficacy and safe breathing conditions (CO2, temperature) were reached when suctioning was at least 60 L/min or 20 L/min > HFNC flow. Five subjects were successfully intubated and anesthetized without ergonomic difficulties and with minimal interference with workflow and an excellent overall assessment by the anesthesiologists. CONCLUSIONS: The vacuum tent effectively minimized aerosol dispersion. Its continuous suction system set at a high suction flow was crucial to avoid the spread of aerosol particles and CO2 rebreathing.


Assuntos
Dióxido de Carbono , Aerossóis e Gotículas Respiratórios , Humanos , Vácuo , Respiração , Nebulizadores e Vaporizadores , Aerossóis
12.
BMJ Open Respir Res ; 11(1)2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38448044

RESUMO

INTRODUCTION: For patients with asthma who remain symptomatic on medium-dose inhaled corticosteroid/long-acting ß2-agonist, add-on long-acting muscarinic antagonist is a treatment option, which can be administered as multiple-inhaler triple therapy (MITT). A high proportion of patients (61.5%-88.2%) discontinue MITT use within 1 year postinitiation; however, which patients discontinue and their treatment patterns at initiation are unknown. This study aimed to understand the demographic, clinical and treatment-related characteristics of patients with asthma who newly initiated MITT, by discontinuation status. METHODS: This retrospective cohort study used administrative data from IBM Truven MarketScan Commercial Claims and Encounters Database with Medicare supplement between 1 January 2016 and 31 December 2019. Adult patients with asthma who initiated MITT between 1 January 2017 and 31 March 2019 were included and were classified based on their discontinuation status. 'Continuous users' had continuous use of MITT and 'discontinuers' discontinued treatment within the 6-month period postinitiation. Demographics and clinical characteristics, asthma treatment use prior to MITT initiation (12-month baseline period), mode of MITT initiation and complexity of regimen were described. RESULTS: Of 4132 patients (mean age: 49.0 years, 67.9% female), 78.0% (n=3224) were discontinuers; 22.0% (n=908) were continuous users. Demographic and other clinical and treatment-related characteristics during baseline were broadly similar between cohorts. A significantly higher proportion of continuous users versus discontinuers had ≥6 dispensed claims for short-acting ß2-agonist canisters (16.0% vs 12.5%; p=0.006) during baseline and initiated a once-daily MITT regimen (35.2% vs 26.2%; p<0.001). Fewer continuous MITT users used a mix of once-daily and twice-daily regimens than those who discontinued MITT (64.3% vs 72.3%; p<0.001). CONCLUSIONS: Most patients with asthma discontinued MITT within 6 months. Results indicate that patients with a history of uncontrolled, symptomatic asthma and those using less complex triple therapy regimens at initiation are less likely to discontinue MITT than patients with controlled asthma and those using a complex MITT regimen.


Assuntos
Asma , Medicare , Idoso , Estados Unidos , Adulto , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Estudos Retrospectivos , Asma/tratamento farmacológico , Nebulizadores e Vaporizadores , Efeitos Psicossociais da Doença
16.
Biomater Adv ; 159: 213823, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38460353

RESUMO

Lung cancer, one of the most common causes of high mortality worldwide, still lacks appropriate and convenient treatment options. Photodynamic therapy (PDT) has shown promising results against cancer, especially in recent years. However, pulmonary drug delivery of the predominantly hydrophobic photosensitizers still represents a significant obstacle. Nebulizing DPPC/Cholesterol liposomes loaded with the photosensitizer curcumin via a vibrating mesh nebulizer might overcome current restrictions. In this study, the liposomes were prepared by conventional thin-film hydration and two other methods based on dual centrifugation. The liposomes' physicochemical properties were determined before and after nebulization, showing that liposomes do not undergo any changes. However, morphological characterization of the differently prepared liposomes revealed structural differences between the methods in terms of lamellarity. Internalization of curcumin in lung adenocarcinoma (A549) cells was visualized and quantified. The generation of reactive oxygen species because of the photoreaction was also proven. The photodynamic efficacy of the liposomal formulations was tested against A549 cells. They revealed different phototoxic responses at different radiant exposures. Furthermore, the photodynamic efficacy was investigated after nebulizing curcumin-loaded liposomes onto xenografted tumors on the CAM, followed by irradiation, and evaluated using positron emission tomography/computed tomography and histological analysis. A decrease in tumor metabolism could be observed. Based on the efficacy of curcumin-loaded liposomes in 2D and 3D models, liposomes, especially with prior film formation, can be considered a promising approach for PDT against lung cancer.


Assuntos
Curcumina , Neoplasias Pulmonares , Humanos , Lipossomos/uso terapêutico , Curcumina/farmacologia , Curcumina/uso terapêutico , Sistemas de Liberação de Medicamentos , Nebulizadores e Vaporizadores , Fármacos Fotossensibilizantes/uso terapêutico , Neoplasias Pulmonares/tratamento farmacológico , Neoplasias Pulmonares/patologia
17.
Mol Pharm ; 21(4): 1848-1860, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38466817

RESUMO

Liposomal carrier systems have emerged as a promising technology for pulmonary drug delivery. This study focuses on two selected liposomal systems, namely, dipalmitoylphosphatidylcholine stabilized by phosphatidic acid and cholesterol (DPPC-PA-Chol) and dipalmitoylphosphatidylcholine stabilized by polyethylene glycol and cholesterol (DPPC-PEG-Chol). First, the research investigates the stability of these liposomal systems during the atomization process using different kinds of nebulizers (air-jet, vibrating mesh, and ultrasonic). The study further explores the aerodynamic particle size distribution of the aerosol generated by the nebulizers. The nebulizer that demonstrated optimal stability and particle size was selected for more detailed investigation, including Andersen cascade impactor measurements, an assessment of the influence of flow rate and breathing profiles on aerosol particle size, and an in vitro deposition study on a realistic replica of the upper airways. The most suitable combination of a nebulizer and liposomal system was DPPC-PA-Chol nebulized by a Pari LC Sprint Star in terms of stability and particle size. The influence of the inspiration flow rate on the particle size was not very strong but was not negligible either (decrease of Dv50 by 1.34 µm with the flow rate increase from 8 to 60 L/min). A similar effect was observed for realistic transient inhalation. According to the in vitro deposition measurement, approximately 90% and 70% of the aerosol penetrated downstream of the trachea using the stationary flow rate and the realistic breathing profile, respectively. These data provide an image of the potential applicability of liposomal carrier systems for nebulizer therapy. Regional lung drug deposition is patient-specific; therefore, deposition results might vary for different airway geometries. However, deposition measurement with realistic boundary conditions (airway geometry, breathing profile) brings a more realistic image of the drug delivery by the selected technology. Our results show how much data from cascade impactor testing or estimates from the fine fraction concept differ from those of a more realistic case.


Assuntos
Broncodilatadores , Traqueia , Humanos , 1,2-Dipalmitoilfosfatidilcolina , Nebulizadores e Vaporizadores , Lipossomos , Aerossóis , Administração por Inalação , Sistemas de Liberação de Medicamentos , Colesterol , Tamanho da Partícula , Desenho de Equipamento
18.
Ann Biomed Eng ; 52(5): 1195-1212, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38509413

RESUMO

Delivery of drugs to the lungs is commonly achieved using nasal and/or oral breathing-assisted techniques. The route of inhalation can substantially change the fate of inhaled droplets. The Respimat® Soft Mist™ Inhaler (SMI) is a commercially available efficient inhaler with 40-60% effectiveness. In the present study, we used computational fluid dynamics (CFD) with a custom setup to investigate the effect of a combined oral/nasal inhalation route on the SMI's regional droplet deposition, size distribution, and flow field. Our setup used a modified induction port (MIP) to mimic nasal inhalation inside the human respiratory tract. Six different oral/nasal flow rate ratios inside the MIP were applied (total flow rate of 30 l/min). An overall good agreement was achieved between simulation outcomes and in vitro results. Our results confirmed that the combined inhalation route affects the flow field, altering the MIP's droplet deposition and size distribution. The lowest depositional loss, mainly in the mouth area, was observed at oral/nasal flow rate ratios of O/N = 1 and O/N = 2 with 3% and 7.7% values, respectively. Droplets with a 2-5 µm diameter range showed the highest droplet mass inside the MIP at all combined flow rates. We observed less intense vortexes followed by a lower level of turbulent kinetic energy at the oral/nasal ratio of 1. Increasing the relative humidity (RH) at oral/nasal flow rate ratios of 0.07, 1, and 14 led to an increase in droplet deposition at the outlet of the MIP.


Assuntos
Laringe , Nebulizadores e Vaporizadores , Humanos , Aerossóis , Administração por Inalação , Pulmão , Tamanho da Partícula , Desenho de Equipamento
19.
Curr Opin Pulm Med ; 30(3): 330-335, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38411213

RESUMO

PURPOSE OF REVIEW: Although digital inhaler systems for asthma management have been commercially available for over a decade, their current use in clinical practice is limited. This review outlines barriers and offers potential solutions to their implementation. RECENT FINDINGS: Digital inhaler systems demonstrate increased controller medication adherence, decreased quick-relief medication use, and improved asthma control. SUMMARY: Use of digital inhaler systems is supported by data from large clinical trials demonstrating improved asthma outcomes. Navigating telemedicine during the coronavirus disease 2019 pandemic has led to advances clearing the path for increased adoption of digital inhaler systems. Progress in areas including patient education and onboarding, clinical management, coding and billing, privacy and security have facilitated implementation in clinical practice.


Assuntos
Asma , Telemedicina , Humanos , Administração por Inalação , Nebulizadores e Vaporizadores , Asma/tratamento farmacológico , Adesão à Medicação
20.
Microb Biotechnol ; 17(2): e14419, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38387963

RESUMO

Inhalation is the preferred route of delivery for anti-asthma and chronic obstructive pulmonary disease (COPD) drugs. The use of this route has demonstrated efficacy in these and other conditions, it offers rapid onset of action, and is associated with minimal systemic exposure, thereby reducing the risk of adverse effects. Therefore, the current brief covers an interesting collection of inhaler action modes, shedding light on their molecular mechanisms and clinical applications for anti-asthma, COPD and antibacterial inhalation therapy. Hence, not only enriches our understanding of inhalation therapy molecular intricacies but also provides a comprehensive overview of the evolving landscape in clinical and antibacterial inhalation therapy. In doing so, it underscores the pivotal role of microbiology and biotechnology in advancing therapeutic approaches that harness the power of inhalation.


Assuntos
Administração por Inalação , Nebulizadores e Vaporizadores , Doença Pulmonar Obstrutiva Crônica , Humanos , Antibacterianos/administração & dosagem , Antibacterianos/uso terapêutico , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...